廚房作為特定場(chǎng)所,有很多設(shè)備,如調(diào)理類、燃?xì)忸悺㈦娖黝惖?。今天就為您?zhǔn)備幾種比較常用的設(shè)備,聊一聊廚房設(shè)備的正確使用方法和保養(yǎng)相關(guān)注意事項(xiàng)的知識(shí)。
Kitchen as a specific place, there are many equipment, such as conditioning class, gas class, electrical appliances, etc. Today, I will prepare several common equipment for you, and talk about the correct use of kitchen equipment and maintenance related precautions.
使用前后要注意按照設(shè)備要求和廚房操作規(guī)范操作,放置可以放置的東西,不能放的東西一定不要放。還要注意檢查面板的焊接口是否牢固、滑輪軌道是否順滑、面板是否有損壞,子彈腳是否牢固等。
Before and after use, pay attention to the operation according to the equipment requirements and kitchen operation specifications, place the things that can be placed, and do not put the things that can not be placed. Also pay attention to check whether the welding interface of the panel is firm, whether the pulley track is smooth, whether the panel is damaged, whether the bullet foot is firm, etc.
避免放置硬物、生銹物和長(zhǎng)時(shí)間放置清潔抹布等。清洗水池壁上沉積礦物質(zhì)時(shí)要用低濃度醋溶液除去,再用清水洗凈,池壁不殘留水滴。含有可腐蝕不銹鋼的成分如氯成分、漂白劑、大量鹽分、鹽酸、硫磺等,產(chǎn)品不宜在水池內(nèi)使用。清潔時(shí)不能用百潔布、不銹鋼刷等易磨損池壁、產(chǎn)生劃痕的東西。

Avoid placing hard objects, rusty objects and cleaning rags for a long time. The mineral deposits on the wall of the pool should be removed with low concentration of vinegar solution, and then washed with clean water, and no water droplets remained on the pool wall. It contains corrosive components of stainless steel, such as chlorine, bleaching agent, large amount of salt, hydrochloric acid, sulfur, etc., so the product should not be used in the pool. When cleaning, do not use cleaning cloth, stainless steel brush and other things that are easy to wear the pool wall and produce scratches.
濟(jì)南廚房排煙的廚房排煙風(fēng)機(jī)排煙罩除消防排煙風(fēng)機(jī)管道的防火閥之外,考慮到廚房高溫工作的原因。其余風(fēng)機(jī)管道的防火閥建議安裝150℃防火閥(與平時(shí)普通風(fēng)機(jī)管道裝置的70℃略有不同),需關(guān)閉其余所有風(fēng)機(jī)(消防補(bǔ)風(fēng)靠外窗及門隙等地方進(jìn)風(fēng))當(dāng)消防排煙風(fēng)機(jī)動(dòng)作時(shí);當(dāng)開(kāi)啟“排油煙風(fēng)機(jī)”時(shí),需同時(shí)(聯(lián)動(dòng))開(kāi)啟“油煙罩補(bǔ)風(fēng)風(fēng)機(jī)”與“工作區(qū)新風(fēng)預(yù)處理風(fēng)機(jī)”。
In addition to the fire damper in the pipe of the smoke exhaust fan of Jinan kitchen, the reason of high temperature work in the kitchen is considered. It is recommended to install 150 ℃ fire damper for other fan pipes (slightly different from the 70 ℃ of ordinary fan duct installation), It is necessary to turn off all other fans (the fire-fighting make-up air is close to the external windows and door gaps) when the fire-fighting smoke exhaust fan is in operation; when the "oil fume exhaust fan" is turned on, the "oil fume hood make-up fan" and the "fresh air pretreatment fan in the working area" should be started simultaneously (linkage).
濟(jì)南酒店廚房排煙罩
Jinan hotel kitchen smoke hood
廚房排煙風(fēng)機(jī)排煙罩的排煙管道未端需要設(shè)置排煙閥,排煙風(fēng)機(jī)排煙罩與排煙管道連接處設(shè)置排煙防火閥。要注意排煙閥與排煙防火閥是功能完全不同的設(shè)備。排煙閥平時(shí)常關(guān),火災(zāi)時(shí)開(kāi),與報(bào)警主機(jī)聯(lián)動(dòng),開(kāi)啟條件是自動(dòng)報(bào)警系統(tǒng)發(fā)生火警(探測(cè)器報(bào)警)消防報(bào)警主機(jī)置于自動(dòng)狀態(tài),排煙閥自動(dòng)開(kāi)啟,聯(lián)動(dòng)排煙風(fēng)機(jī)啟動(dòng)。排煙防火閥是平時(shí)常開(kāi),火災(zāi)時(shí)也是開(kāi)啟狀態(tài),但當(dāng)煙氣溫度達(dá)到280℃時(shí),排煙防火閥自動(dòng)關(guān)閉,聯(lián)動(dòng)已經(jīng)開(kāi)啟的風(fēng)機(jī)停止運(yùn)行。
The smoke exhaust valve should be set at the end of the smoke exhaust pipe of the smoke exhaust hood of the kitchen smoke exhaust fan, and the smoke exhaust fire damper should be set at the joint of the smoke exhaust hood and the smoke exhaust pipe of the smoke exhaust fan. It should be noted that smoke exhaust valve and smoke fire damper are completely different equipment. The smoke exhaust valve is normally closed at ordinary times and opened in case of fire, which is linked with the alarm host. The opening condition is that the automatic alarm system has a fire alarm (detector alarm), the fire alarm host is in automatic state, the smoke exhaust valve is opened automatically, and the linkage smoke exhaust fan is started. The smoke exhaust fire damper is normally open at ordinary times and is also open in case of fire. However, when the flue gas temperature reaches 280 ℃, the smoke fire damper will automatically close and the fan that has been opened will stop running.
上一篇:廚房排煙工程安裝的靜音工作如何做到合理?
下一篇:山東通風(fēng)管道制作安裝|風(fēng)管的三種類型