現(xiàn)如今,為了凈化室內(nèi)環(huán)境,保障呼吸的健康,很多的朋友都會(huì)選擇安裝新風(fēng)系統(tǒng)通風(fēng)管道,管道的安裝著實(shí)為我們的生活帶來(lái)了更多的方便,不僅為我們提供了新鮮的空氣,還能調(diào)節(jié)室內(nèi)的濕度,為幫助大家更好的使用新風(fēng)系統(tǒng)通風(fēng)管道,我們特意為您整理了以下安裝和清洗方法供您參考。
Nowadays, in order to purify the indoor environment and ensure the health of breathing, many friends will choose to install the fresh air system ventilation duct. The installation of the pipe really brings more convenience to our life. It not only provides us with fresh air, but also adjusts the indoor humidity. In order to help you better use the ventilation duct of the fresh air system, we specially arrange for you Installation and cleaning methods for your reference.
一、新風(fēng)系統(tǒng)通風(fēng)管道的安裝:
1、 Installation of ventilation duct of fresh air system:
1、要使設(shè)計(jì)的新風(fēng)系統(tǒng)通風(fēng)管道達(dá)到較低的風(fēng)阻和噪音,新風(fēng)輸出口、排風(fēng)輸出口和主機(jī)之間的連接都應(yīng)該采取安裝消聲器或用軟連接來(lái)連接。
1. In order to reduce the wind resistance and noise of the ventilation duct of the fresh air system, the connection between the fresh air outlet, exhaust outlet and the main engine should be installed with muffler or connected with soft connection.
2、對(duì)于新風(fēng)系統(tǒng)主機(jī)安裝在吊頂上,應(yīng)該在吊桿上安裝減震器。
2. For the main unit of fresh air system installed on the ceiling, shock absorber should be installed on the suspender.
3、新風(fēng)系統(tǒng)主機(jī)、金屬風(fēng)管都應(yīng)該做保溫處理。
3. The main engine and metal air duct of fresh air system should be insulated.
新風(fēng)系統(tǒng)風(fēng)口的位置選擇:原則上要均勻
Location selection of air outlet of fresh air system: uniform in principle
4、新風(fēng)系統(tǒng)風(fēng)口的位置選擇:原則上要均勻,保障室內(nèi)的新風(fēng)量能夠達(dá)到平衡。不宜開風(fēng)口處:風(fēng)管的尾部、轉(zhuǎn)彎處和變徑處。
4. The location selection of fresh air system outlet: in principle, it should be uniform to ensure that the indoor fresh air volume can reach balance. Not suitable for tuyere opening: the tail of the air duct, turning and reducing.
5、新風(fēng)系統(tǒng)風(fēng)閥的安裝:近端與末端處主風(fēng)管與支管交接處需要安裝風(fēng)量調(diào)節(jié)閥,管道系統(tǒng)中間可以使用氣流導(dǎo)流片或風(fēng)量調(diào)節(jié)閥。
5. Installation of air valve in fresh air system: air volume regulating valve shall be installed at the junction of main air duct and branch pipe at near end and end, and air guide vane or air volume regulating valve can be used in the middle of pipeline system.
6、新風(fēng)系統(tǒng)通風(fēng)管道之間相連接時(shí)應(yīng)使用法蘭相連接,且應(yīng)加橡膠填充條。
6. When the ventilation pipes of fresh air system are connected, they should be connected by flange, and rubber filler strip should be added.
7、新風(fēng)系統(tǒng)主機(jī)用于隱蔽安裝時(shí),需要預(yù)留維護(hù)檢修口。
7. When the main machine of fresh air system is used for concealed installation, it is necessary to reserve maintenance access.
二、新風(fēng)系統(tǒng)通風(fēng)管道的清洗:
2、 Cleaning of ventilation duct of fresh air system:
1、用裝有攝相頭的機(jī)器人進(jìn)入管道拍攝記錄風(fēng)管內(nèi)污染狀況;根據(jù)住宅的建筑圖紙,會(huì)同客戶詳細(xì)制定管道清洗施工方案;
1. The robot equipped with camera head is used to enter the pipeline to shoot and record the pollution condition in the air duct; according to the building drawings of the residence, the construction scheme of pipeline cleaning is formulated in detail with the customer;
2、在新風(fēng)系統(tǒng)通風(fēng)管道適當(dāng)部位開施工孔,在兩開孔位置外側(cè)用封堵氣囊堵住管道兩端;用軟管將集塵器連接到其中一個(gè)施工孔,使風(fēng)管內(nèi)產(chǎn)生負(fù)壓氣流,讓灰塵與污物被吸入集塵器內(nèi);選擇適當(dāng)?shù)那逑疵ⅲ霉艿狼逑礄C(jī)器人或軟軸毛刷進(jìn)行管道清洗;清洗以后,由機(jī)器人拍照記錄,確認(rèn)清洗質(zhì)量;
2. Open construction holes at appropriate parts of ventilation pipes of fresh air system, and block both ends of pipes with blocking air bags outside the two opening positions; connect the dust collector to one of the construction holes with hose, so as to generate negative pressure air flow in the air duct, so that dust and dirt can be inhaled into the dust collector; select appropriate cleaning brush, and use pipeline cleaning robot or flexible shaft brush to clean the pipeline; after cleaning, the dust collector is connected to one of the construction holes The robot takes photos and records to confirm the cleaning quality;
3、當(dāng)清洗質(zhì)量被認(rèn)可后,在清洗過(guò)的管道內(nèi)噴灑消毒劑;清理、移動(dòng)清洗設(shè)備到下一段管道清洗;用相同材料重新封閉開口處;清理修復(fù)風(fēng)管被損保濕層;清潔場(chǎng)地,以保障不影響下一步工作。
3. After the cleaning quality is approved, spray disinfectant in the cleaned pipeline; clean and move the cleaning equipment to the next section of pipeline; re seal the opening with the same material; clean and repair the damaged moisture layer of air duct; clean the site to ensure that the next step work will not be affected.
不知道小編介紹的內(nèi)容大家了解了嗎?關(guān)于山東通風(fēng)管道的更多資訊請(qǐng)關(guān)注我們的官網(wǎng),后期會(huì)有更多相關(guān)信息的更新,幫助您了解更多
山東通風(fēng)管道
I don't know the content of the introduction? For more information about Shandong ventilation pipeline, please pay attention to our official website. There will be more relevant information update in the future to help you learn more about Shandong ventilation pipeline
上一篇:通風(fēng)管道中風(fēng)閥及風(fēng)管的注意事項(xiàng)
下一篇:濟(jì)南酒店廚房排煙罩設(shè)計(jì)安裝方法